Classification of gas stove solenoid valves

- 2022-03-18-

At present, the gas stove solenoid valve can be divided into two kinds. One is a thermocouple solenoid valve, and one is an ion abutment solenoid valve. We can distinguish according to the type of flameout protection, and the general thermocouple is on the right side of the knob valve. , Ions, generally near the airway elbow. One is directly installed on the side of the gas intake, controlling the intake of the two stoves, one is the intake port of each furnace.

The height of the thermocouple of gas stove should be substantially flat to the height of the fire, and it should be noted that the distance between the thermocouple and the fire cover should be taken. The thermocouple and the fire cover cannot be too far, generally maintained at 4 ± 0.5mm distance is best, if the installation position is too low, the thermocouple is insufficient, the thermal potential is not enough, does not cause the solenoid valve, the installation position is too high The flame is too large, it is easy to burn the thermocouple, the same reason, too far, will also be insufficient, and the solenoid valve will not be sucked.